SR-700 DC-100/600 DA-300/600/1200 BC/SC/MU Battery Charger
DC-100 to DC-600
Q1. Is there a derating for the 24 to 12 volt converters for continuous use?

A1. For the 24 to 13.8V DC-DC converters (i.e. DC series), their model numbers indicate their
maximum current. Below is a table for your information.
Model DC-100 DC-150 DC-300 DC-400 DC-600
Maximum Current (10 minutes) 10A 15A 30A 40A 60A
Continuous Current (3 hours) 7A 12A 20A 30A 40A
Continuous Current (24 hours) 5A 10A 15A 20A 30A
For continuous loading the unit temperature will raise about 25 degree C above ambient